I only had the relays replaced. by Paulmold on Fri Dec 28, 2018 7:01 am. Trumatic S3002 L P Gas Heater + Ultraheat Spare Parts. Nepasuje k topením S3002 K, S5002 K a S5002 do roku 4/98. It could be mounted on the pcb (box like) or adjacent. The Ultra Heat is equipped with a fan that allows the warm air from the heater to be passed around the caravan via a system of pipes. Gas pressure regulators and power supply products round off the extensive product range. I have a swift challenger and have had some problems with truma ultraheat. Truma Trumatic C Control Panel 34000-59000 [Product Id: 6226] Out of stock. I've found only relays or the two overtemp stats seem to cause the problems or badly sited remote temperature sensors. Related: truma heater truma ultraheat control truma ultraheat pcb truma ultrastore ultraheat truma heater truma caravan heater truma gas fire truma water heater. Not speaking with a lot of knowledge of Truma. Re: Truma Ultraheat no green light . then they won't last 10 minutes! Instrucciones de uso Sidan 15 ¡Ilévalas en el vehiculo! All listings - Current page Auction Buy it now Classified Ads. Refine. Info £119.86. CCG 21320 Truma Ultraheat Parts List For full list of replacement parts for the Truma Ultraheat heater, click - Spec - Parts for other models are available on request 01926 640489 or email sales@caravanparts.co.uk Truma S 3002 Flue ducting and Front Case. Your Truma Ultra heat unit is responsible for the heating of your caravan. Being mechanical it would be more likely to fail than the pcb. What is the function of these cables? I have a swift challenger and have had some problems with truma ultraheat. Truma Ultraheat Units. It is a duel fuel unit, this means that it runs on 240v mains electric and gas. [Reception]  that would point to the wrong relays being fitted or the correct ones not fitted well? Info £77.20. The one I fitted was a 2va as opposed to a 1.5va. [Company Listings]  As stated above the relays on the circuit board are of poor quality and often burn out. Would it be possible to get a breakdown of the coloured cables and their function. [Competitions]  Could there be separate fuses for the different settings?  Thanks in advance. The 3 relays are mounted on a pcb within a grey box at the rear of the fire the ones fitted originaly were rated at 10 amps these contacts burn out but the relay coils still operate.later pcbs from about 2004 were fitted with 16 amp relays. 4 results for truma ultraheat Save truma ultraheat to get e-mail alerts and updates on your eBay Feed. Click here to read our updated forum rules. That's really useful. Control panel for Truma S3002 fires. In-between seasons you can heat with Truma Ultraheat alone. Truma No. Apologies if I gave you the impression I changed the whole board. Brugsanvisning Side 13 Skal medbringes i køretøjet! As you have not got a remote stat fitted, the room stat is in the switch and a poor connection at either end of the loom would get worse as the 'room' gets a little warmer, this then could well make the stat act erratically and switch the relays as yours are doing. You must log in or register to reply here. clicking through the different heat settings quietly! Truma S 3002 Flue ducting and Installation Box. [Event Diary]  As I stated in first posting the initial problem appeared to be the relays as they were clicking a lot. Truma Ultraheat. Any further advice or suggestions would be very much appreciated. Firstly the main pcb behind the fire has relays which burn out. When we replaced the pcb we couldnt remember the order of the coloured cables. Your 'good' board though from your mates van also seems faulty to me, are you sure it works on all setting in his van?? The new relays seem to be working perfectly ie. Truma Ultraheat is the ideal addition to S 3004 and S 5004 heaters in your caravan. These seem fine and therefore eliminates the stats. Initially I thought it was the relays and had them replaced after reading the forum as they were clicking constantly. Best Match. Truma Spares. Just trying to eliminate the different parts. Truma S Heaters; Truma Ultraheat; Van & Water Combi Heating. Initially he was unsure about the mains power supply to the heater but it is reading 240v so we think its ok.  Do you have any suggestions what the problem could be or how we could eliminate the different areas? Quick View. [Caravan Sites & Camping]  If so which of the coloured cables would we need to attach? Truma Ultraheat PC Board 30030-70900 [Product Id: 6520] Out of stock. Summary of Contents for Truma Ultraheat Solo. They have begun to click frantically again and no heat. T5 Bike Racks. Is is possible for you to have a look at my pcb if I send it to you before I consider replacing the switch? The general fault is that the UItraheat elements will only work on 500W but not on the higher power settings. Truma PRIMA Leisure is a dedicated Truma parts stockist and specialist, stocking a full range of after-market fittings for many of Truma's most popular products. Truma Corp 2800 Harman Dr Elkhart, IN 46514 USA. Depending on your individual warmth requirements, choose one of three operating levels: 500W, 1000W or 2000W. Like . The other variable is the temperature dial itself, it's only a simple 'volume' control and this could be dirty inside giving the same results. The cause of stat failure I'm told is down to a slightly loose spade connection, loose causes high resistance, resistance causes heat and heat melts the stat! Truma Control Panel for C3402, C6002 and Therme [Product Id: 6223] Out of stock. Any tips anyone - my Truma heater is working perfectly well on 500w setting but won't go on either 2kw or 3kw settings which I needed last week! Info £39.99. View and Download Truma Ultraheat S 3004 installation instructions manual online. In the last few years I have repaired my and the brother in laws Truma Ultraheat. Easier to replace the pcb than the relays individually and costs around £80 Secondly there are 2 thermal cut out sensors. Using my own pcb and loom connection and working switch from my friends caravan, the heater is functioning but only on 1kw. I hope this post has been some help if only to point out what could be faulty on the PCB apart from the relays. The switch would seem to be the only thing left to test maybe it's the connection between? Ultraheat S 3004 electric heater pdf manual download. Got a hold of an old pcb for the truma ultraheat and fitter a 9v transformer as Arc Systems suggested. more Format Format. No. My very patient and understanding spark has checked over several things but we can't get it going. Add to Cart. So for anyone coming across a blown transformer in the future fit a 230v - 9v one.-----Ghostpiper In-between seasons you can heat with Truma Ultraheat alone. Info £63.82. Upgradedreplacement relays for Truma Ultraheat comes with the controller all leads . JavaScript is disabled. This works perfectly well and the transformer is a lot easier to get a hold of. [Tent Reviews], Please note we are not responsible for the content of external sites & any reviews represent the author's personal view only. Contact Us they don't last that long if in constant use, still, I think one of the thermostats is open circuit and these are replaced individually. Fixed cost of £40 + from £6 return p&p (UK) The p&p charge covers the postal return of your PCB. As suggested, we have since checked the continuity between the black wires and also the blue and green. The new relays seem to be working perfectly ie. Add to cart. Could this mean that the relays are not just fitted correctly as the elements are both ok. Or could it be a combination of faulty switch and relays? Mar 2, 2017 - Parts for space heating and water heating appliances and control panels As the same thing is happening with a second pcb, could it be the control switch or do these ever give any problems. Not leaving me feedback or giving me anything less in any of the four sections has a great effect on my selling performance . As yours is still under warranty I would let them sort it for you. Time: ending soonest; The green LED on the control switch is working so the 12v transformer must be ok. First my memory was correct, the second stat is connected to the board between green and blue. I had them replaced on the board and had hoped this would sort the problem. But if the 240v has failed I would search out the relay. Součástí základního balení termostat a 3 m kabelu k ovládacímu panelu. In both cases I changed the pcb’s for ones with beefier relays from a supplier on ebay. Here at Apuljack Engineering we have repaired countless Truma Ultraheat boards with a variety of fau.. £19.08 Ex Tax: £15.90. The Truma product range includes heating and air conditioning systems, through to hot water generators and manoeuvring systems for caravans. The problem is not the amperage rating but the design of the control, 16A ones then, (of the same type), will at best only last a bit longer than 10A. Info £132.30. The 3 relays are mounted on a pcb within a grey box at the rear of the fire the ones fitted originaly were rated at 10 amps these contacts burn out but the relay coils still operate.later pcbs from about 2004 were fitted with 16 amp relays. I've changed dozens of relays and not encountered any problems, I've not encountered a faulty switch either, although I've acquired lots of faulty switches from dealers which work fine when I test them?! Initially the heater did work and then it stopped working. Truma/Carver Remote Control Handset for Original Single Axle Caravan Mover [Product Id: 6340] The red as said is common, the other colours supply voltage to one element for 1kw, both for 2kw or both in series for 500w. All of the products in all product areas are among the most high performance in the market. We also connected a temporary supply to the elements both white and green and they are definately working. Rapidly turning it a dozen or more times might settle it down and prove where the fault lies? Sort: Best Match. £4.76 Off. Any pictures or diagrams would be helpful. It could be mounted on the pcb (box like) or adjacent. Apuljack Truma Ultraheat Relay & Transformer Kit. If the relays are faulty, this can reduce the power of the heater. Truma Ultraheat Electric Heater Additional electric heater to heat caravans faster in any weather. Pack of 3 replacement quality relays to repair the common fault on Ultraheat circuitboards. This is no longer the case. Relays not working: My model has settings at 500W, 1KW and 2KW. 1 at 125 and 1 at 175, these apparently are some what trickier to replace but come in at less than a tenner each. davemarshall Member Posts: 27 Joined: 2018-05-19 Location: Wigan Auto-Sleeper: Nuevo Vehicle Year: 2006. [Virtual Brochure]  The elements are connected between green and red, and white and red, (red being common), around 55 to 58 ohms resistance across each element is correct. If the stats are faulty can they be replaced or do they come as part of the element? Truma Ultraheat is the ideal addition to S 3004 and S 5004 heaters in your caravan. but if yours have even worse contact material? Grove Description 01 30030-98600 Control Ultraheat <04/02 02 10010-78900 Screw B 2.9 x 25 04 30030-98500 898500 Control panel (GB) 05 00000-01000 Screw M 3.5 x 25 UK) 06 00000-11100 Screw cover UK 07 00000-01100 Control knob UK 08a 30030 … As there were 2 black ones we were unsure of where they should go. Sorry for all the questions just trying to get an understanding of the workings of the heater and then hopefully get a solution. This seems to eliminate the element. Fiamma VW T5 Bike Racks; Unfortunately not! Please report any error, Caravan Repairs, Servicing and Maintenance. Apuljack Truma Ultraheat Relay & Transformer Kit. If so they will work, no need to bypass anything and mess about with mains voltage! The relays seem to be working when we first put the pcb back in. Back to the pcb. Carver Truma Operation Video. In order to post a reply you will need to register, or if already registered please log in here, Free UKCampsite.co.uk Window Sticker  -  Recommend to Friend, [Message Forums]  ... Citroen Jumper/Relay; Mercedes Vito; Peugeot Boxer; VW T5. Initially I thought it was the relays and had them replaced after reading the forum as they were clicking constantly. Is this relevant or are they both do the same function? Really helpful post, thanks Produkt pasuje k topením Truma S3004 a S5004, S3002 od roku 81 a novější a S5002 od roku 4/98 a novější. The green LED is lit. [Shop!] Phone: +1 (855) 558-7862 Fax: +1 (574) 538-2426. Exploded Diagrams; Sales Information; Instructions; Truma S 3002. Depending on your individual warmth requirements, choose one of three operating levels: 500W, 1000W or 2000W. Apuljack Engineering offers this simple repair kit to replace and upgrade the relays and transformer on the Truma Ultraheat main PCB. Also for: Ultraheat s … I really don't know now, you are now saying you replaced the relays and not the whole control board? The additional electric heater warms motor homes and caravans quickly and reliably. clicking through the different heat settings quietly! The additional electric heater warms motor homes and caravans quickly and reliably. [Caravans & Motorhomes For Sale]  [Features / Advice]  Not speaking with a lot of knowledge of Truma. Brand: Apuljack Engineering; Product Code: AE-P-HE-00012; Availability: 5; £19.08; Ex Tax: £15.90 Source for Fanmaster mk1 - thermal cut out. The original contact material is not much cop to say the least! Upgradedreplacement relays for Truma Ultraheat control circuitboard. We have checked the resistence across each element - green/red which we think is 2 kw was reading 55.3 ohms - white/red which we think is 1 kw was reading 54 ohms. Being mechanical it would be more likely to fail than the pcb. David. For a better experience, please enable JavaScript in your browser before proceeding. [Contact Us]  Beyond this, Truma produce the much-loved Powrtouch motor-mover manoeuvring systems for caravans, plus … You don't say how long since you replaced the board? Truma Ultraheat Control Panel 30030-98400 - **OBSELTE** [Product Id: 6294] Out of stock. I borrowed a pcb from a friends caravan whose heater was working perfectly and it does exactly the same thing. ex Shipping. Seems by mention of Maplins this is an old post, but in answer to question indeed I do still offer this service, your best though to contact me by the phone number on my website. Přídavná elektrická spirála Ultraheat se montuje mezi topné těleso a zadní kryt topení. That is they were clicking through the heat settings but the heater only worked for a few minutes. ... Truma Ultraheat; Truma VarioHeat; Fire Type Heaters. Good luck. pack of 3 replacement quality relays to repair the common fault on ultraheat circuitboards. Black with a hint of brown. This is generally caused to failure of the original relays going faulty. I have new stats in stock as well as serviced exchange boards with uprated relays. But if the 240v has failed I would search out the relay. The new ones fitted must have the same resistance across the coil as the originals or near as don't matter anyway. I had a look at an element with red cable on one side and green, blue and white on the other. They are actually pcb mounted,which the panel behind the fire,are you changing the relays because only 1 element is working? The part no for the maplin relays are N30AW about. Page 1 In voertuig meenemen! Unfollow truma ultraheat to stop getting updates on your eBay Feed. Truma Roof Mounted Air-Conditioning; Under Bench Air-Conditioning. could well be true?! I would appeciate any help you can offer. Truma 5m Extension Cable for C3402, C4002, C6002 [Product Id: 6219] Out of stock. When I replace the switch with my own it begins to click frantically and the heater doesn't work. Is it possible to test the elements themselves by bypassing the main controls. In my case, I tested the power input to the caravan to confirm that all my relays were working correctly, with the caravan taking the correct amount of current for each heat setting The relays click a lot and elements heated for a very brief period. Top Cover for Truma S3002 fires. Please note this is for repair of your board not supply of a new one. We use Royal Mail First Class (non recorded) as a standard return postal service.This has a compensation limit of £46.